FAULTGLASS is a closed-loop fault investigator for brownfield process plants, where digital telemetry and manual equipment coexist and the one measurement that decides the diagnosis is the one nobody wired. THE PROBLEM: THE UNINSTRUMENTED LAST METER Main pumps and flowmeters stream to the PLC; the chokepoints that settle root cause (filter-bank inlet and outlet Bourdon gauges, local ΔP, manual valves) do not. When a cartridge bank loads, permeate falls from ~2,000 to ~1,500 L/h, suction pressure and motor current sag, TDS creeps up, and every PLC fault bit stays NORMAL. From the control room, a loaded cartridge, a feed-supply problem, a failing high-pressure pump and a membrane fault look alike, and they cost very differently: guess wrong and you pull a healthy pump or replace membranes that were fine. So diagnosis dominates downtime: readings radioed in, P&IDs from memory, valves turned by hand with no record of how, closure by judgement. Anomaly detectors and manual copilots stop at this boundary. They flag the symptom; they cannot observe the cause or prove the fix. THE SOLUTION FAULTGLASS carries the investigation across that boundary, with the field operator as the agent's sensing and actuation extension: 1. Perceive: a read-only Modbus edge feeds an open-weight watcher that screens 30 s statistical cards every 10 s for coordinated drift no single alarm catches. 2. Reason: a long-horizon agent runs a differential diagnosis over plant topology, SOPs and prior incidents, holding feed, pump, membrane and cartridge hypotheses as open, rejected, supported or confirmed on telemetry evidence. 3. Reach: field-only tags are unreadable by construction, so the agent stops instead of hallucinating and dispatches a targeted task. The phone Field Companion locates the gauges in a 3D digital twin, and the investigation checkpoints until the physical world answers. 4. Measure: SAM 3.1 isolates each dial from phone-photo clutter, Wonder reads the psi scale, and code computes inlet-minus-outlet ΔP against a 12 psi restriction gate. The operator's Marathi/English voice note is structured and tolerance-checked against the photos. 5. Actuate safely: the V-113 backwash is proposed only when ΔP is restricted and runs only after Commander approval. The lever video is tracked to prove the SOP's staged close: two hand-driven moves separated by a still hold of at least 2 s. 6. Verify: an independent verifier closes the incident only on sustained recovery in fresh telemetry. RESULT Piloted on a mineral-water bottling plant in Maharashtra, India: gauge photos, valve clips and operator voice captured on site, process telemetry from a physics-based simulator behind a Modbus PLC emulator. The loop runs end to end, from silent drift to verified recovery at ~92% of baseline (~350 L/h restored), with cartridge replacement kept open as the follow-up. No PLC writes, no retrofit, every link auditable.
More from Meta Global AI Developer Hackathon
Cardo turns the world around you into Kurdish flashcards. Kurdish is spoken by tens of millions of people, but it has very few learning tools, and most…

oqed is an LLM-guided superoptimizer for x86-64. You point it at a C or C++ project and it does the rest: - builds the project and runs its workload…

Playtest Agent plays a game from screenshots, looks for bugs, then replays each report and has a judge check it. I make games alone. Solo developers and…

Open-source npm malware detection on Meta's models: a live monitor that flags new malware about a day before the public lists, a Muse agent that investigates…

Video2URDF turns one short phone video of a real articulated object (a laptop lid, a drawer, a desk lamp, a microwave door) into a measured URDF/MJCF a robot…

Glimmer Scope opens up Muse Glimmer 30B so you can see and steer the concepts it thinks with. I trained sparse autoencoders on nine layers of Glimmer's…